Supply flow (T1 / Kv)Return line (T2 / Δp)230V / 24V / NTC control
LST EN 1264 · G 1" kolektorius (PN10, Tmax +110 °C) · Eurokonusas 3/4" × 16×2,0 mm
Select assembly callout pin [01–06] on blueprint or list:
[01] Tiekiama sija su srauto matuokliais (rotametrai 0–5 l/min)Kaunas warehouse stock: Sandėlyje Kaune (atsarginiai rotametrai)
Material / Spec: Nerūdijančio plieno AISI 304 arba žalvario G 1" sija su skaidriais 0–5 l/min rotametrais
Srautas l/min reguliuojamas sukant rotametro žiedą, kol plūdė pasiekia projektinę vertę.
EN 1264 balansavimas: vieno 16×2,0 mm kontūro ilgis L ≤ 80–100 m (ΔT = 5 K), srautas nustatomas rotametru (0,5–3,5 l/min) pagal kilpos ilgį.
All [01–06] sub-assemblies, adapters, and gaskets stocked at Eigulių St. 21, Kaunas warehouse (10+ yr service support).
02 / Required tools & 4-step mounting sequence
+Matching threaded union or compression adapter sized to your pipe diameter (DN15 / DN20 / DN25)
+Calibrated spanner or torque wrench for thread/union tightening without housing distortion
Technical specifications (Z012010)
Viessmann
Manufacturer
Viessmann
Model / SKU
Z012010
Gamintojo kodas (MPN)
Z012010
Gamintojo serija
Viessmann Katilai serija
Pajungimo matmuo / sriegis
Standartizuota gamyklinė ŠVOK connection
Vardinis slėgis / galia / tūris
PN10 / Vardinis gamyklinis režimas
Korpuso / mazgo medžiaga
AISI 304 stainless steel + nickel-plated bronze
Engineering node configuration · Vytautas
Vytautas recommends: compatible components for complete installation
Node role:Hydronic & HVAC assembly component
Vytautas engineering compatibility note (Z012010)
Verified mating components for Viessmann (Z012010) matched by connection standard (DN / thread / M30×1.5 / RA Click) and hydraulic compatibility.
Practical engineering answers for Viessmann Prijungimo komplektas n kolektorių grupei up to 15 m 2 ploto (1,51 m 2) (Z012010)
Will Viessmann Prijungimo komplektas n kolektorių grupei up to 15 m 2 ploto (1,51 m 2) (Z012010) fit my existing heating system?
Yes, this Viessmann unit (SKU Z012010, category: Boilers & boiler room equipment) is manufactured to European EN 12828 hydronic standards. Verify the connection thread or nominal size (e.g. DN15 1/2", DN20 3/4", M30×1.5 or Danfoss RA Click) – our engineering advisor Vytautas lists directly compatible mating components on this page.
How does Viessmann Z012010 differ from budget alternatives?
Genuine Viessmann components use corrosion-resistant alloys (DZR brass, bronze or stainless steel) and calibrated flow paths, preventing valve sticking, water-hammer noise and premature seal leaks over 10+ heating seasons.
What mating fittings are needed to install Z012010 in one visit?
When installing Viessmann Prijungimo komplektas n kolektorių grupei up to 15 m 2 ploto (1,51 m 2) (Z012010, price on request), check whether you need matching union tailpieces, Eurocone adapters, a mating thermostatic head or actuator. See the compatible parts section above.
How to avoid the most common installation mistake with Z012010?
Always observe the flow-direction arrow on the housing, depressurise the loop before fitting, and never apply hemp or tape onto flat union gaskets or O-ring cones.
Viessmann Viessmann Prijungimo komplektas n kolektorių grupei iki 15 m 2 ploto (1,51 m 2) (Z012010) – patikrinkite jungties sriegį ir sistemos parametrus prieš montavimą.
Suderinamumą pasitikslinkite su mūsų inžinieriumi (+370 693 97098) arba pagal įrenginio techninį pasą
Source: Manufacturer technical catalog (Danfoss / IMI Hydronic / HERZ / Haier / Gorenje 2025–2026) and LST EN 215 / EN 12828 / EN 303-5 standard
Verification note: Solid-fuel boiler door aperture and flange dimensions vary by production year and kW rating – before ordering a door conversion kit or pellet burner, verify exact dimensions against the boiler passport or with a „Gilės inžinerija“ engineer (+370 693 97098).
Official Viessmann supply chain · 24-month warranty & after-sales service
Full on-site installation & commissioning available (+370 693 97098 · info@gilesinzinerija.lt)
+System shut-off and air-bleeding check before commissioning the circuit
01 · Verify thread & nominal diameter (DN)
Confirm that Z012010 connection matches the supply/return pipework and flow direction arrow.
02 · Mount the body onto the isolated branch
Depressurise the heating circuit, fit the union tailpiece and tighten to factory torque.
03 · Set hydraulic pre-setting / control parameter
Adjust the flow scale (Kvs / l/h) or controller setting according to room or boiler loop load.
04 · Pressurise, bleed air & verify tightness
Refill the loop, vent trapped air and verify leak-free operation under operating temperature.
Darbinė temperatūra / įtampa
up to +110 °C (uždara sistema)
Atitikties standartas
LST EN 303-5 / EN 12828
Taikymo sritis
Katilai ir katilinės įranga (Viessmann inžinerinės šildymo, vėsinimo ir vandentiekio sistemos)
Engineer checklist before installation
Verify before adding to cart
01Does the connection size and DN of Z012010 match your manifold, boiler or radiator port?
02Have you added matching union fittings, actuators or thermostatic heads to your cart?
03Is the operating pressure (PN) and temperature rating suitable for your heating circuit?
Engineer pro tip: When installing Viessmann (Z012010), never wind hemp onto flat gasket seats or Eurocone O-ring cones – seal only tapered pipe threads.
In stockKaTRI3850150